Skip to content
English
  • There are no suggestions because the search field is empty.

Starting a XIBU TOWEL hybrid new

You want to restart a XIBU TOWEL hybrid device.

Due to the XIBU TOWEL hybrid having a capacitor the device is also powered on without an energyBOX or battery connected to it. When the device needs to be restarted you need to manually restart the device.

  1. Open the device's lid with the XIBU key.
  2. Check if the circuit board cover has these openings.

    Towel Reset 1
  3. Bend a paper clip to the following shape.
    • Both ends need to be the same length, so both contacts at the circuit board get touched (no danger for humans or the device).

      Towel Reset 2-1
  4. Insert the bend paper clip into the openings.

    Towel Reset 3-1
  5. The XIBU TOWEL hybrid device should restart. (Noticeable when the device blinks green, red and blue)